What does accessible egress mean?

An accessible means of egress, as defined by the IBC, is a “continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way.” Where more than one means of egress is required from any accessible space.

How many exits are required for ADA?

The IBC requires at least one accessible means of egress and at least two accessible means of egress where more than one means of egress is required by other sections of the building code.

Can an elevator serve as a means of egress?

1, Exception 1 states that in buildings sprinklered in accordance with NFPA 13 or 13R, an elevator is not required to serve as an accessible means of egress on floors provided with a horizontal exit located at or above the levels of exit discharge.

Do all exits need to be ADA accessible?

All entrances and exterior and interior exit doors regardless of the occupant load shall be made accessible to persons with disabilities. Separate facilities are required where provided for the non disabled.

What is a path of egress?

A means of egress is an unobstructed path to leave buildings, structures, and spaces. A means of egress is comprised of exit access, exit, and exit discharge.

When does a building need an accessible means of egress?

The 1991 Standards require the same number of accessible means of egress to be provided as the number of exits required by applicable building and fire codes. The IBC requires at least one accessible means of egress and at least two accessible means of egress where more than one means of egress is required by other sections of the building code.

How many means of egress are required by the IBC?

The IBC requires at least two means of egress from all buildings and spaces within buildings with very few exceptions. Buildings or spaces with 500 or more occupants are required to have at least three means of egress. Buildings or spaces with more than 1,000 occupants are required to have at least four means of egress.

When is a means of egress permitted in a mercantile space?

For example, in a mercantile space, a single means of egress is permitted when there are fewer than 50 calculated occupants in the space or the exit access travel distance is less than 75 feet. The distance is measured along the path of travel, not diagonally across the space.

What do you mean by means of egress?

Compliance with a later edition may be possible under the provision for “equivalent facilitation” (§103) if it is comparable to, or stricter than, the referenced editions. Means of Egress A means of egress is an unobstructed path to leave buildings, structures, and spaces. A means of egress is comprised of exit access, exit, and exit discharge.