Flow Switch Tester, Flexible Reducing Coupling, Electronic Dry Pipe Valve Accelerator, Advanced Hydraulic Calculations, Extended Coverage Upright Pendent Sprinklers, Grooved Fittings, CPVC Fire Sprinkler Pipe Fittings
Water-Based Fire Suppression Systems: Sprinklers
Tyco Fire and Building Products is a leading manufacturer of water-based fire suppression system components and ancillary building construction products. We provide effective fire protection and construction solutions for residential, commercial, industrial and institutional buildings. FLUSH PENDENT SPRINKLERS Model TY-QRF, 5.6 K-factor UPRIGHT PENDENT SPRINKLERS Series TY-L, 5.6 and 8.0 K-factorSeries TY-FRL, 2.8, 5.6, and 8.0 K-factorSeries TY-B, 2.8, 5.6, and 8.0 K-factorSeries TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor HORIZONTAL SIDEWALL SPRINKLERS Series TY-L, 5.6 K-factorSeries TY-FRL, 5.6 K-factor HORIZONTAL VERTICAL SIDEWALL SPRINKLERS Series TY-B, 5.6 K-factorSeries TY-FRB, 5.6 K-Factor CONCEALED PENDENT SPRINKLERS Series RFII Quick Response, Standard Response (5 mm bulb), 5.6 K-Factor, ``Royal Flush II`` EXTENDED COVERAGE UPRIGHT SPRINKLERS Model EC-25, K-factor 25.2. EXTENDED COVERAGE UPRIGHT PENDENT SPRINKLERS Series EC-11 and EC-14. EXTENDED COVERAGE PENDENT SPRINKLERS Series EC-8Series EC-5 Model EPEC HORIZONTAL SIDEWALL SPRINKLERS Model SW-20 and SW-24, 11.2 K-factor EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS Series EC-5Series TY-FRB, 5.6, 8.0 K-factor, Series TY-FRL, 5.6, 8.0 K-factor SIDEWALL SPRINKLERS 8.0 K-factor, Model CHEC CONCEALED PENDENT SPRINKLERS Model ELOC, 11.2 K-factor Series RFII, 5.6 K-Factor EARLY SUPPRESSION FAST RESPONSE SPRINKLERS Model ESFR-25 Pendent Sprinklers, K-factor 25.2 EARLY SUPPRESSION FAST RESPONSE PENDENT SPRINKLERS Model ESFR-17, K-factor 16.8Model ESFR-1, K-factor 14.0 EARLY SUPPRESSION FAST RESPONSE UPRIGHT SPRINKLERS Model ESFR-17, K-factor 16.8 UPRIGHT SPECIFIC APPLICATION CONTROL MODE SPRINKLER Ultra K17, K-factor 16.8 UPRIGHT PENDENT SPRINKLERS Model K17-231, K-factor 16.8 Series ELO-231TM, K-factor 11.2 Series ELO-231B, K-factor 11.2 Series ELO-231FRB, K-factor 11.2 LARGE DROP UPRIGHT SPRINKLERS Model LD, K-factor 11.2 UPRIGHT PENDENT INTERMEDIATE LEVEL SPRINKLERS Series TY-B, K-factor 5.6 and 8.0 Series TY-FRB, K-factor 5.6 and 8.0 Series TY-L, K-factor 5.6 and 8.0 Series TY-FRL, K-factor 5.6 and 8.0 RESIDENTIAL PENDENT SPRINKLERS Series LFII, 4.9 K-factor RESIDENTIAL PENDENT RECESSED CONCEALED SPRINKLERS Series LFII, K-factor 6.9 RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLERS Series LFII, K-factor 4.2, K-factor 5.6 FLAT PLATE RESIDENTIAL CONCEALED PENDENT SPRINKLERS Series LFII, K-factor 4.2 RESIDENTIAL, FLUSH PENDENT SPRINKLERS Series LFII, K-factor 4.2 RESIDENTIAL, FLUSH HORIZONTAL SIDEWALL SPRINKLERS Series LFII, K-factor 4.2 RESIDENTIAL, CONCEALED PENDENT SPRINKLER, DOMED PLATE Series LFII, K-factor 4.9 DRY TYPE SPRINKLERS Series DS-1, K-factor 5.6 Series DS-2, K-factor 11.2 DRY SPRINKLER BOOT Model DSB-1 DRY PENDENT CONCEALED SPRINKLERS Series DS-C, K-factor 5.6 Series DS-ECC, K-factor 5.6 ATTIC SPRINKLERS Fusible Link Automatic Sprinklers HORIZONTAL AND PENDENT VERTICAL SIDEWALL WINDOW SPRINKLERS Model WS, K-factor 5.6 UPRIGHT COMBUSTIBLE CONCEALED SPACE SPRINKLER Model CC1, K-factor 2.8 Model CC2, K-factor 4.2 and 5.6 HIGH PRESSURE SPRINKLERS Series TY300-B, K-factor 5.6 Series TY300-FRB, K-factor 5.6 INSTITUTIONAL PENDENT SPRINKLERS Model TFP PH2, K-factor 5.6Model TFP MAX, K-factor 5.6 INSTITUTIONAL HORIZONTAL SIDEWALL SPRINKLERS Model TFP PH5, K-factor 5.6 Model TFP MAX, K-factor 5.6 CONVENTIONAL SPRINKLERS Series TY-B, K-factor 5.6 and 8.0Series TY-B, K-factor 80 and 115Series TY-FRB, K-factor 5.6 and 8.0 PENDENT AND UPRIGHT SPRINKLERS Issue D Quartzoid, K-Factor 5.6 and 8.0Stainless Steel Quartzoid, K-Factor 5.6 RECESSED ESCUTCHEONS, PROTECTIVE PAINT CAPS Styles 10, 20, 30, 40 and 50 ONE-PIECE FLAT SPRINKLER ESCUTCHEON TWO-PIECE ADJUSTABLE SPRINKLER ESCUTCHEON HEAD SPRINKLER HEAD CABINET SPRINKLER GUARDS Model G1 & G4Model G2 GUARDS WITH SHIELDS Model G1/S1 & G4/S3, WS-2, WSG-2 OPEN DIRECTIONAL SPRAY NOZZLES Type D3 Protectospray AUTOMATIC DIRECTIONAL SPRAY NOZZLES Type EA-1 Protectospray HIGH VELOCITY OPEN DIRECTIONAL SPRAY NOZZLES Type HV CORNICE SPRINKLERS, WINDOW SPRINKLERS Issue AIssue B FOAM-WATER SPRINKLER Issue B-1 OPEN NON-AUTOMATIC NOZZLES Type AM10 AquaMist NozzlesType AM4 AquaMist Nozzles BLOW-OFF PLUG OPEN SPRINKLER PROTECTOSPRAY NOZZLE MULSIFYRE PROJECTOR AUTOMATIC NOZZLES Type AM 24 AquaMist Nozzles
Tyco Fire and Building Products is a leading manufacturer of water-based fire suppression system components and ancillary building construction products. We provide effective fire protection and construction solutions for residential, commercial, industrial and institutional buildings.
Model TY-QRF, 5.6 K-factor
Series TY-L, 5.6 and 8.0 K-factorSeries TY-FRL, 2.8, 5.6, and 8.0 K-factorSeries TY-B, 2.8, 5.6, and 8.0 K-factorSeries TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor
Series TY-L, 5.6 K-factorSeries TY-FRL, 5.6 K-factor
Series TY-B, 5.6 K-factorSeries TY-FRB, 5.6 K-Factor
Series RFII Quick Response, Standard Response (5 mm bulb), 5.6 K-Factor, ``Royal Flush II``
Model EC-25, K-factor 25.2.
Series EC-11 and EC-14.
Series EC-8Series EC-5 Model EPEC
Model SW-20 and SW-24, 11.2 K-factor
Series EC-5Series TY-FRB, 5.6, 8.0 K-factor, Series TY-FRL, 5.6, 8.0 K-factor
8.0 K-factor, Model CHEC
Model ELOC, 11.2 K-factor Series RFII, 5.6 K-Factor
Model ESFR-25 Pendent Sprinklers, K-factor 25.2
Model ESFR-17, K-factor 16.8Model ESFR-1, K-factor 14.0
Model ESFR-17, K-factor 16.8
Ultra K17, K-factor 16.8
Model K17-231, K-factor 16.8 Series ELO-231TM, K-factor 11.2 Series ELO-231B, K-factor 11.2 Series ELO-231FRB, K-factor 11.2
Model LD, K-factor 11.2
Series TY-B, K-factor 5.6 and 8.0 Series TY-FRB, K-factor 5.6 and 8.0 Series TY-L, K-factor 5.6 and 8.0 Series TY-FRL, K-factor 5.6 and 8.0
Series LFII, 4.9 K-factor
Series LFII, K-factor 6.9
Series LFII, K-factor 4.2, K-factor 5.6
Series LFII, K-factor 4.2
Series LFII, K-factor 4.9
Series DS-1, K-factor 5.6 Series DS-2, K-factor 11.2
Model DSB-1
Series DS-C, K-factor 5.6 Series DS-ECC, K-factor 5.6
Fusible Link Automatic Sprinklers
Model WS, K-factor 5.6
Model CC1, K-factor 2.8 Model CC2, K-factor 4.2 and 5.6
Series TY300-B, K-factor 5.6 Series TY300-FRB, K-factor 5.6
Model TFP PH2, K-factor 5.6Model TFP MAX, K-factor 5.6
Model TFP PH5, K-factor 5.6 Model TFP MAX, K-factor 5.6
Series TY-B, K-factor 5.6 and 8.0Series TY-B, K-factor 80 and 115Series TY-FRB, K-factor 5.6 and 8.0
Issue D Quartzoid, K-Factor 5.6 and 8.0Stainless Steel Quartzoid, K-Factor 5.6
Styles 10, 20, 30, 40 and 50
Model G1 & G4Model G2
Model G1/S1 & G4/S3, WS-2, WSG-2
Type D3 Protectospray
Type EA-1 Protectospray
Type HV
Issue AIssue B
Issue B-1
Type AM10 AquaMist NozzlesType AM4 AquaMist Nozzles
Type AM 24 AquaMist Nozzles
Valves and Accessories
RESIDENTIAL DOMESTIC SHUTOFF VALVE Model RSV-1 ALARM CHECK VALVE Model AV-1-300Model AV-1-175 RISER CHECK VALVE Model CV-1FR RISER MANIFOLD 513, 513D/513R WATER MOTOR ALARM Model WMA-1 PRESSURE RELIEF TRIM RETARD CHAMBER Model RC-1 DRY PIPE VALVE Model F3061 (Flange x Groove)Model DPV-1 ELECTRONIC DRY PIPE VALVE ACCELERATOR Model QRS DRY PIPE ACCELERATOR Model ACC-1 EXHAUSTER Model BB AUTOMATIC AIR MAINTENANCE DEVICE Model AMD-1Model AMD-2 AUTOMATIC NITROGEN MAINTENANCE DEVICE Model AMD-3 RED E-CABINET Model DV-5 DELUGE VALVE Model DV-5Model DV-3 THERMAL CONTROL VALVE Model TCV-1 DRY PILOT ACTUATOR Model DP-1 MANUAL CONTROL STATIONS Model MC-1 AUTOMATIC SHUT-OFF VALVE Model ASV-1 FAIL-SAFE VALVE Model FSV-1 FIXED TEMPERATURE RELEASE Model FTR-1 SINGLE INTERLOCK SYSTEM Model DV-5Model DV-1Model DV-3 DOUBLE INTERLOCK SYSTEM Model DV-5Model DV-1Model DV-3 BUTTERFLY VALVES, WAFER AND LUG STYLE Series 8000FP CHECK VALVES Model CV-2 FUSIBLE LINKS Issue C, 50lb PIPE LINE STRAINERS Model AModel B-1Model C FIRE DEPARTMENT CONNECTION 86 Straight 90 Degree AUTOMATIC DRAIN BALL DRIP VALVE Model F789 SECTIONAL TEST & DRAIN Model F350 SIGHT FLOW CONNECTIONS Model F1321 AUTOMATIC SUPERVISORY AIR SUPPLY Model G16AC812 AUTOMATIC DRAIN VALVE Model AD-1 SOLENOID VALVES
Model RSV-1
Model AV-1-300Model AV-1-175
Model CV-1FR
513, 513D/513R
Model WMA-1
Model RC-1
Model F3061 (Flange x Groove)Model DPV-1
Model QRS
Model ACC-1
Model BB
Model AMD-1Model AMD-2
Model AMD-3
Model DV-5
Model DV-5Model DV-3
Model TCV-1
Model DP-1
Model MC-1
Model ASV-1
Model FSV-1
Model FTR-1
Model DV-5Model DV-1Model DV-3
Series 8000FP
Model CV-2
Issue C, 50lb
Model AModel B-1Model C
86 Straight 90 Degree
Model F789
Model F350
Model F1321
Model G16AC812
Model AD-1
Grooved Products
Tyco Fire & Building Products produces ductile iron, ASTM A-536, Grade 65-45-12 for all of its Grinnell grooved products. Once the base iron is produced, magnesium is added in precise measurements to develop the ductile iron grade. The metal is tested chemically, physically, and microscopically prior to being released for production. Once cast, the ductile iron is again checked to ensure conformance with these specifications. Rubber Injection: Tyco Fire & Building Products understands the complexity of providing gaskets capable of exceeding customer demands. With state of the art rubber injection presses and tooling, we are able to mold several types of rubber compounds to meet the various needs of the mechanical market. The gaskets are manufactured in our facility in Alabama and each gasket is inspected to ensure it is defect free. Physical tests are performed on the gaskets to verify compliance with specifications such as ASTM D-2000. The Paint Process: Grinnell Grooved Products are painted using a computer controlled semi-automatic process. This process ensures that each product is spray washed, dried, pre-heated, dipped and fully cured prior to being assembled or packaged for shipment. All painted parts are quality controlled to maintain consistent paint coverage and surface condition. Tooling: Our engineering department provides product designs to our pattern centers as well as contracted pattern makers. The Grinnell patterns and our foundry molding machines are capable of providing the closest tolerance parts available using the green sand method of casting. BUTTERFLY VALVE Model BFV-1 CHECK VALVE Model CV-1F GROOVED FITTINGS FLEXIBLE COUPLING Figure 705 FLEXIBLE REDUCING COUPLING Figure 716 FLEXIBLE COUPLING Figure 707 RIGID COUPLING Figure 772 MECHANICAL TEES Figure 730 FLANGE ADAPTER Figure 71
Tyco Fire & Building Products produces ductile iron, ASTM A-536, Grade 65-45-12 for all of its Grinnell grooved products. Once the base iron is produced, magnesium is added in precise measurements to develop the ductile iron grade. The metal is tested chemically, physically, and microscopically prior to being released for production. Once cast, the ductile iron is again checked to ensure conformance with these specifications. Rubber Injection: Tyco Fire & Building Products understands the complexity of providing gaskets capable of exceeding customer demands. With state of the art rubber injection presses and tooling, we are able to mold several types of rubber compounds to meet the various needs of the mechanical market. The gaskets are manufactured in our facility in Alabama and each gasket is inspected to ensure it is defect free. Physical tests are performed on the gaskets to verify compliance with specifications such as ASTM D-2000. The Paint Process: Grinnell Grooved Products are painted using a computer controlled semi-automatic process. This process ensures that each product is spray washed, dried, pre-heated, dipped and fully cured prior to being assembled or packaged for shipment. All painted parts are quality controlled to maintain consistent paint coverage and surface condition. Tooling: Our engineering department provides product designs to our pattern centers as well as contracted pattern makers. The Grinnell patterns and our foundry molding machines are capable of providing the closest tolerance parts available using the green sand method of casting.
Model BFV-1
Model CV-1F
Figure 705
Figure 716
Figure 707
Figure 772
Figure 730
Figure 71
BlazeMaster
CPVC FIRE SPRINKLER PIPE FITTINGS BlazeMaster CPVC Fire Sprinkler Pipe Fittings has becomes first non-metallic pipe approved for use in unfinished basements and exposed system risers. EXPOSED SYSTEM RISERS BlazeMaster CPVC Fire Sprinkler Pipe Fittings are now listed by Underwriters Laboratories, Inc. (UL) for use in unfinished basements with exposed solid wood joist installations in accordance with NFPA 13D and in exposed system risers in accordance with NFPA 13D and 13R. BlazeMaster CPVC pipe is the only non-metallic pipe listed by UL for these applications. NO BLOCK HANGER HEAD SET MOUNTING BRACKET
BlazeMaster CPVC Fire Sprinkler Pipe Fittings has becomes first non-metallic pipe approved for use in unfinished basements and exposed system risers.
BlazeMaster CPVC Fire Sprinkler Pipe Fittings are now listed by Underwriters Laboratories, Inc. (UL) for use in unfinished basements with exposed solid wood joist installations in accordance with NFPA 13D and in exposed system risers in accordance with NFPA 13D and 13R. BlazeMaster CPVC pipe is the only non-metallic pipe listed by UL for these applications.
Fire Sprinkler Drawing Packages
FIRE SPRINKLER DRAWING PACKAGES, SPRINKCAD N1, SPRINKCAD PRO II SprinkCAD N1 and SprinkCAD Pro II are complete fire sprinkler drawing packages. A library of tools is included to allow the drawing of basic building units such as walls, ceilings, beams, etc., as well as sprinkler piping elements. Perform multiple calculations until the desired pipe sizes are achieved and stocklist the plan without the need to run another program. Integrated AutoCAD, head layout, piping, hydraulic calculation and stocklisting modules deliver a complete fire sprinkler solution. No need to purchase AutoCAD as a separate package – N1 is built on AutoCAD 2002 technology. Existing drawings, catalogs, report and strategy files work unchanged with SprinkCAD N1 or SprinkCAD Pro II, which is compatible with AutoCAD 2000, 2000i and 2002. None of the procedures for designing, calcing, or listing a job need be changed. Existing drawings, catalogs, report and strategy files work unchanged with SprinkCAD Pro II. FIRE SPRINKLER 3D DESIGN PACKAGE, SPRINKCAD 3D SprinkCAD 3D is a comprehensive fire sprinkler 3D design package that produces true three-dimensional piping plans and views. SprinkCAD 3D includes the latest SprinkCALC and SprinkSLIC programs giving the designer total control of the necessary tools to create a complete project. SprinkCAD 3D can also be used with the optional SprinkFDT program to calculate the trip and water delivery times for dry type systems. SprinkCAD 3D is a true 3D system – everything is designed in 3D-model space. The sprinkler designer can still work in a 2D plan view and use preset ISO views for viewing, thus making it an easy transition from 2D to 3D for those new to 3D views. Until now, creating three-dimensional objects in AutoCAD† has been slow and tedious. SprinkCAD 3D`s tools automate the 3D drawing process and allow sprinkler designers to lay out three-dimensional systems with relative ease. ADVANCED HYDRAULIC CALCULATIONS, SPRINKCALC Did the AHJ just ask for the advanced hydraulic calculations to be balanced and presented in metric using the Darcy-Weisbach method? No problem. Welcome to the newest and most advanced hydraulic calculation program available today...SprinkCALC. Metrics, U.S. units, mixed units... Hazen-Williams, Darcy-Weisbach... it doesn`t matter, SprinkCALC does it all and with ease. Work in familiar units and let the system do the conversions. MULTILEVEL LOOPED DRY SYSTEM, SIMPLE TREE SYSTEM Simply change the desired calculation method and in seconds view the new results. Quickly customize or build any pipe or fitting equivalent table for use on any material available today or tomorrow. Simple input screens allow complex sprinkler systems to be input and edited with ease. Calculate anything from a simple tree system to a multilevel looped dry system fed by a wet grid supplied by fire pump and city water. SPRINKCODE, INTERACTIVE CODE SELECTOR Quick! What`s the required density and area for...? Whether it`s an estimate or the final design, this interactive code selector is an essential member of your staff. The codes are not getting any simpler. When the complex details of storage height, ceiling height, aisle widths, pallets, bins, encapsulation, commodities, plastics, etc., make the difference between a bid and a contract, between a proper design or a review nightmare, you`ll be glad SprinkCODE is there to guide you. FIRE PUMP CURVES, DISPLAY FLOW TEST CURVES Intelligent interactive screens offer the choices needed to quickly and accurately narrow the options for the desired system density and coverage area, (or special application sprinkler). Within seconds the available options can be displayed for any NFPA 13 1999 code requirement. NFPA 13 1996, NFPA 231/231C 1995 and 1998 are also referenced. During the process of selecting the desired hazard options, simply select the NFPA 13 1999 requirement detail and the page of the code will appear for review or printing. The flow graph option quickly displays the 1.85 hydraulic graph and includes options to display flow test curves, fire pump curves and combined curves as desired. SPRINKSLIC, FIRE SPRINKLER STOCK LISTING Right on site! Ain`t that SLIC? The name of the game is ``pipe on the job`` and fire sprinkler stock listing is the bridge between design and installation. SprinkSLIC has power and depth yet is the easiest stand-alone stocklisting software to learn and use. Fast input and clear screens make creating and interpreting detailed pipe fabrication a breeze. SprinkSLIC is built on the popular SLIC program that has been used industry wide for many years. This new version makes use of the latest technologies and brings this powerful program new life. Fully Windows compatible — say goodbye to DOS screens and printing problems HYDRAULICALLY CALCULATED GRIDDED SYSTEMS, SPRINKFDT Welcome to SprinkFDT, the first dramatic advancement in fire protection technology since the introduction of hydraulically calculated girded systems over 30 years ago. SprinkFDT is the latest software offering from SprinkCAD. FLUID DELIVERY TIME SprinkFDT (Fluid Delivery Time) now empowers a sprinkler designer to accurately predict the time it takes to trip a dry valve and deliver water to the remote area without the requirement of a physical trip test. Simple input and summary screens allow the user to quickly define a sprinkler system and evaluate the need for an accelerator or design modification. DOUBLE INTERLOCK PREACTION SYSTEMS James Golinveaux address the applicability of SprinkFDT to Double Interlock Preaction Systems in the 2002 edition of NFPA 13. SprinkFDT uses the same interface and file structure as our powerful SprinkCALC program making hydraulic calculation and delivery time calculation input even quicker. Simply calculate the system using SprinkCALC and then open SprinkFDT, select the open sprinklers and evaluate the dry system performance.
SprinkCAD N1 and SprinkCAD Pro II are complete fire sprinkler drawing packages. A library of tools is included to allow the drawing of basic building units such as walls, ceilings, beams, etc., as well as sprinkler piping elements. Perform multiple calculations until the desired pipe sizes are achieved and stocklist the plan without the need to run another program. Integrated AutoCAD, head layout, piping, hydraulic calculation and stocklisting modules deliver a complete fire sprinkler solution.
No need to purchase AutoCAD as a separate package – N1 is built on AutoCAD 2002 technology. Existing drawings, catalogs, report and strategy files work unchanged with SprinkCAD N1 or SprinkCAD Pro II, which is compatible with AutoCAD 2000, 2000i and 2002. None of the procedures for designing, calcing, or listing a job need be changed. Existing drawings, catalogs, report and strategy files work unchanged with SprinkCAD Pro II.
SprinkCAD 3D is a comprehensive fire sprinkler 3D design package that produces true three-dimensional piping plans and views. SprinkCAD 3D includes the latest SprinkCALC and SprinkSLIC programs giving the designer total control of the necessary tools to create a complete project. SprinkCAD 3D can also be used with the optional SprinkFDT program to calculate the trip and water delivery times for dry type systems.
SprinkCAD 3D is a true 3D system – everything is designed in 3D-model space. The sprinkler designer can still work in a 2D plan view and use preset ISO views for viewing, thus making it an easy transition from 2D to 3D for those new to 3D views. Until now, creating three-dimensional objects in AutoCAD† has been slow and tedious. SprinkCAD 3D`s tools automate the 3D drawing process and allow sprinkler designers to lay out three-dimensional systems with relative ease.
Did the AHJ just ask for the advanced hydraulic calculations to be balanced and presented in metric using the Darcy-Weisbach method? No problem. Welcome to the newest and most advanced hydraulic calculation program available today...SprinkCALC. Metrics, U.S. units, mixed units... Hazen-Williams, Darcy-Weisbach... it doesn`t matter, SprinkCALC does it all and with ease. Work in familiar units and let the system do the conversions.
Simply change the desired calculation method and in seconds view the new results. Quickly customize or build any pipe or fitting equivalent table for use on any material available today or tomorrow. Simple input screens allow complex sprinkler systems to be input and edited with ease. Calculate anything from a simple tree system to a multilevel looped dry system fed by a wet grid supplied by fire pump and city water.
Quick! What`s the required density and area for...? Whether it`s an estimate or the final design, this interactive code selector is an essential member of your staff. The codes are not getting any simpler. When the complex details of storage height, ceiling height, aisle widths, pallets, bins, encapsulation, commodities, plastics, etc., make the difference between a bid and a contract, between a proper design or a review nightmare, you`ll be glad SprinkCODE is there to guide you.
Intelligent interactive screens offer the choices needed to quickly and accurately narrow the options for the desired system density and coverage area, (or special application sprinkler). Within seconds the available options can be displayed for any NFPA 13 1999 code requirement. NFPA 13 1996, NFPA 231/231C 1995 and 1998 are also referenced. During the process of selecting the desired hazard options, simply select the NFPA 13 1999 requirement detail and the page of the code will appear for review or printing. The flow graph option quickly displays the 1.85 hydraulic graph and includes options to display flow test curves, fire pump curves and combined curves as desired.
Right on site! Ain`t that SLIC? The name of the game is ``pipe on the job`` and fire sprinkler stock listing is the bridge between design and installation. SprinkSLIC has power and depth yet is the easiest stand-alone stocklisting software to learn and use. Fast input and clear screens make creating and interpreting detailed pipe fabrication a breeze.
SprinkSLIC is built on the popular SLIC program that has been used industry wide for many years. This new version makes use of the latest technologies and brings this powerful program new life. Fully Windows compatible — say goodbye to DOS screens and printing problems
Welcome to SprinkFDT, the first dramatic advancement in fire protection technology since the introduction of hydraulically calculated girded systems over 30 years ago. SprinkFDT is the latest software offering from SprinkCAD.
SprinkFDT (Fluid Delivery Time) now empowers a sprinkler designer to accurately predict the time it takes to trip a dry valve and deliver water to the remote area without the requirement of a physical trip test. Simple input and summary screens allow the user to quickly define a sprinkler system and evaluate the need for an accelerator or design modification.
James Golinveaux address the applicability of SprinkFDT to Double Interlock Preaction Systems in the 2002 edition of NFPA 13. SprinkFDT uses the same interface and file structure as our powerful SprinkCALC program making hydraulic calculation and delivery time calculation input even quicker. Simply calculate the system using SprinkCALC and then open SprinkFDT, select the open sprinklers and evaluate the dry system performance.
New Products
FLOW SWITCH TESTER, ZONECHECK Zonecheck complies with NFA 25 Quarterly Switch Test Requirements. It reduces testing time and saves up to 400 gallons per switch annually with simple key-switch operation. It doesn`t open inspectors test valve or activate the fire pump. DSB-1 DRY SPRINKLER BOOT The DSB-1 dry sprinkler boot will combat the potentially damaging temperature changes that can adversely affect dry sprinklers installed in freezers. DSB-1 dry sprinkler boot is an EPDM, 50 durometertype rubber boot designed for installation with all vertical, or pendent, dry sprinklers. Once installed, the boot creates an airtight seal, eliminating the build up of potentially dangerous condensation by maintaining consistent temperatures both outside and within the freezer area. PRE-ACTION AUTOMATIC SPRINKLER, DD-1 CONDENSATE DRAIN, DELUGE SPRINKLER The DD-1 Condensate Drain is a pre-manufactured drum drip for installation in dry-pipe sprinkler, deluge sprinkler and pre-action automatic sprinkler systems. The DD-1 Condensate Drain is made from electric-resistance-welded carbon and alloy steel mechanical tubing, ASTM A513. After the machining process is complete, the 1`` male outlets shall have a wall thickness greater than or equal to 0.133 inches and an O.D. of 1.315 inches. The DD-1 Condensate Drain is quick and easy to install. AQUAMIST SYSTEM The ``MCC`` Pump Skid Package is the self-contained control center of the AquaMist System. The compact skid unit has been professionally designed and assembled to ease system installation and to meet the most stringent project requirements. Power must be provided for the control cabinet and pump controller. Detection circuits must be installed and wired to the control cabinet.An adequate water supply must be piped to the pump supply piping inlet. HEAVY DENSITY SPRINKLER SYSTEMS AquaMist Systems utilize the newest and most unique nozzles developed and approved for fire protection. They offer an alternative to gaseous, foam, and heavy density sprinkler systems. By utilizing a higher pressure than a normal sprinkler system, but a 50-80% lower water flow, the AquaMist Systems use less water more effectively, reduce pipe sizes and labor costs, and minimize cleanup and water damage.
Zonecheck complies with NFA 25 Quarterly Switch Test Requirements. It reduces testing time and saves up to 400 gallons per switch annually with simple key-switch operation. It doesn`t open inspectors test valve or activate the fire pump.
The DSB-1 dry sprinkler boot will combat the potentially damaging temperature changes that can adversely affect dry sprinklers installed in freezers. DSB-1 dry sprinkler boot is an EPDM, 50 durometertype rubber boot designed for installation with all vertical, or pendent, dry sprinklers. Once installed, the boot creates an airtight seal, eliminating the build up of potentially dangerous condensation by maintaining consistent temperatures both outside and within the freezer area.
The DD-1 Condensate Drain is a pre-manufactured drum drip for installation in dry-pipe sprinkler, deluge sprinkler and pre-action automatic sprinkler systems. The DD-1 Condensate Drain is made from electric-resistance-welded carbon and alloy steel mechanical tubing, ASTM A513. After the machining process is complete, the 1`` male outlets shall have a wall thickness greater than or equal to 0.133 inches and an O.D. of 1.315 inches. The DD-1 Condensate Drain is quick and easy to install.
The ``MCC`` Pump Skid Package is the self-contained control center of the AquaMist System. The compact skid unit has been professionally designed and assembled to ease system installation and to meet the most stringent project requirements. Power must be provided for the control cabinet and pump controller. Detection circuits must be installed and wired to the control cabinet.An adequate water supply must be piped to the pump supply piping inlet.
AquaMist Systems utilize the newest and most unique nozzles developed and approved for fire protection. They offer an alternative to gaseous, foam, and heavy density sprinkler systems. By utilizing a higher pressure than a normal sprinkler system, but a 50-80% lower water flow, the AquaMist Systems use less water more effectively, reduce pipe sizes and labor costs, and minimize cleanup and water damage.
:: IDS Plastics :: IDS Water ::IDS Packaging::IDS Publishing/Media ::IDS Healthcare Management ::IDS Environment::IDS Power/Energy::
Industry IDS, Inc. – Online Tradeshow, Exhibition, & Buyers Guide Solutions