TYCO FIRE AND BUILDING PRODUCTS

Water-Based Fire Suppression Systems: Sprinklers
Valves and Accessories
Grooved Products
BlazeMaster
Fire Sprinkler Drawing Packages
New Products



Flow Switch Tester, Flexible Reducing Coupling, Electronic Dry Pipe Valve Accelerator, Advanced Hydraulic Calculations, Extended Coverage Upright Pendent Sprinklers, Grooved Fittings, CPVC Fire Sprinkler Pipe Fittings


Tyco Fire and Building Products is a leading manufacturer of water-based fire suppression system components and ancillary building construction products. We provide effective fire protection and construction solutions for residential, commercial, industrial and institutional buildings.

FLUSH PENDENT SPRINKLERS 

Model TY-QRF, 5.6 K-factor

UPRIGHT PENDENT SPRINKLERS

Series TY-L, 5.6 and 8.0 K-factor
Series TY-FRL, 2.8, 5.6, and 8.0 K-factor
Series TY-B, 2.8, 5.6, and 8.0 K-factor
Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor

HORIZONTAL SIDEWALL SPRINKLERS 

Series TY-L, 5.6 K-factor
Series TY-FRL, 5.6 K-factor

HORIZONTAL VERTICAL SIDEWALL SPRINKLERS 

Series TY-B, 5.6 K-factor
Series TY-FRB, 5.6 K-Factor

CONCEALED PENDENT SPRINKLERS 

Series RFII Quick Response, Standard Response (5 mm bulb), 5.6 K-Factor, ``Royal Flush II``

EXTENDED COVERAGE UPRIGHT SPRINKLERS

Model EC-25, K-factor 25.2. 

EXTENDED COVERAGE UPRIGHT PENDENT SPRINKLERS

Series EC-11 and EC-14. 

EXTENDED COVERAGE PENDENT SPRINKLERS

Series EC-8
Series EC-5
Model EPEC

HORIZONTAL SIDEWALL SPRINKLERS

Model SW-20 and SW-24, 11.2 K-factor 

EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS

Series EC-5
Series TY-FRB, 5.6, 8.0 K-factor, 
Series TY-FRL, 5.6, 8.0 K-factor

SIDEWALL SPRINKLERS

8.0 K-factor, Model CHEC 

CONCEALED PENDENT SPRINKLERS 

Model ELOC, 11.2 K-factor
Series RFII, 5.6 K-Factor

EARLY SUPPRESSION FAST RESPONSE SPRINKLERS

Model ESFR-25 Pendent Sprinklers, K-factor 25.2

EARLY SUPPRESSION FAST RESPONSE PENDENT SPRINKLERS

Model ESFR-17, K-factor 16.8
Model ESFR-1, K-factor 14.0

EARLY SUPPRESSION FAST RESPONSE UPRIGHT SPRINKLERS

Model ESFR-17, K-factor 16.8

UPRIGHT SPECIFIC APPLICATION CONTROL MODE SPRINKLER

Ultra K17, K-factor 16.8

UPRIGHT PENDENT SPRINKLERS

Model K17-231, K-factor 16.8
Series ELO-231TM, K-factor 11.2
Series ELO-231B, K-factor 11.2
Series ELO-231FRB, K-factor 11.2

LARGE DROP UPRIGHT SPRINKLERS

Model LD, K-factor 11.2

UPRIGHT PENDENT INTERMEDIATE LEVEL SPRINKLERS

Series TY-B, K-factor 5.6 and 8.0
Series TY-FRB, K-factor 5.6 and 8.0
Series TY-L, K-factor 5.6 and 8.0
Series TY-FRL, K-factor 5.6 and 8.0

RESIDENTIAL PENDENT SPRINKLERS

Series LFII, 4.9 K-factor

RESIDENTIAL PENDENT RECESSED CONCEALED SPRINKLERS

Series LFII, K-factor 6.9

RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLERS

Series LFII, K-factor 4.2, K-factor 5.6

FLAT PLATE RESIDENTIAL CONCEALED PENDENT SPRINKLERS

Series LFII, K-factor 4.2

RESIDENTIAL, FLUSH PENDENT SPRINKLERS

Series LFII, K-factor 4.2

RESIDENTIAL, FLUSH HORIZONTAL SIDEWALL SPRINKLERS

Series LFII, K-factor 4.2

RESIDENTIAL, CONCEALED PENDENT SPRINKLER, DOMED PLATE

Series LFII, K-factor 4.9

DRY TYPE SPRINKLERS

Series DS-1, K-factor 5.6
Series DS-2, K-factor 11.2

DRY SPRINKLER BOOT

Model DSB-1  

DRY PENDENT CONCEALED SPRINKLERS

Series DS-C, K-factor 5.6
Series DS-ECC, K-factor 5.6

ATTIC SPRINKLERS

Fusible Link Automatic Sprinklers

HORIZONTAL AND PENDENT VERTICAL SIDEWALL WINDOW SPRINKLERS

Model WS, K-factor 5.6

UPRIGHT COMBUSTIBLE CONCEALED SPACE SPRINKLER

Model CC1, K-factor 2.8
Model CC2, K-factor 4.2 and 5.6

HIGH PRESSURE SPRINKLERS

Series TY300-B, K-factor 5.6
Series TY300-FRB, K-factor 5.6

INSTITUTIONAL PENDENT SPRINKLERS

Model TFP PH2, K-factor 5.6
Model TFP MAX, K-factor 5.6

INSTITUTIONAL HORIZONTAL SIDEWALL SPRINKLERS

Model TFP PH5, K-factor 5.6
Model TFP MAX, K-factor 5.6

CONVENTIONAL SPRINKLERS

Series TY-B, K-factor 5.6 and 8.0
Series TY-B, K-factor 80 and 115
Series TY-FRB, K-factor 5.6 and 8.0

PENDENT AND UPRIGHT SPRINKLERS

Issue D Quartzoid, K-Factor 5.6 and 8.0
Stainless Steel Quartzoid, K-Factor 5.6

RECESSED ESCUTCHEONS, PROTECTIVE PAINT CAPS

Styles 10, 20, 30, 40 and 50

ONE-PIECE FLAT SPRINKLER ESCUTCHEON

TWO-PIECE ADJUSTABLE SPRINKLER ESCUTCHEON

HEAD SPRINKLER HEAD CABINET

SPRINKLER GUARDS

Model G1 & G4
Model G2

GUARDS WITH SHIELDS

Model G1/S1 & G4/S3, WS-2, WSG-2

OPEN DIRECTIONAL SPRAY NOZZLES

Type D3 Protectospray

AUTOMATIC DIRECTIONAL SPRAY NOZZLES

Type EA-1 Protectospray

HIGH VELOCITY OPEN DIRECTIONAL SPRAY NOZZLES

Type HV

CORNICE SPRINKLERS, WINDOW SPRINKLERS

Issue A
Issue B

FOAM-WATER SPRINKLER

Issue B-1

OPEN NON-AUTOMATIC NOZZLES

Type AM10 AquaMist Nozzles
Type AM4 AquaMist Nozzles

BLOW-OFF PLUG

OPEN SPRINKLER

PROTECTOSPRAY NOZZLE

MULSIFYRE PROJECTOR

AUTOMATIC NOZZLES

Type AM 24 AquaMist Nozzles




Extended Coverage Upright Pendent Sprinklers

Early Suppression Fast Response Pendent Sprinklers1

RESIDENTIAL DOMESTIC SHUTOFF VALVE

Model RSV-1

ALARM CHECK VALVE

Model AV-1-300
Model AV-1-175

RISER CHECK VALVE

Model CV-1FR

RISER MANIFOLD

513, 513D/513R

WATER MOTOR ALARM

Model WMA-1

PRESSURE RELIEF TRIM

RETARD CHAMBER

Model RC-1

DRY PIPE VALVE

Model F3061 (Flange x Groove)
Model DPV-1

ELECTRONIC DRY PIPE VALVE ACCELERATOR

Model QRS

DRY PIPE ACCELERATOR

Model ACC-1

EXHAUSTER

Model BB

AUTOMATIC AIR MAINTENANCE DEVICE

Model AMD-1
Model AMD-2

AUTOMATIC NITROGEN MAINTENANCE DEVICE

Model AMD-3

RED E-CABINET

Model DV-5

DELUGE VALVE

Model DV-5
Model DV-3

THERMAL CONTROL VALVE

Model TCV-1

DRY PILOT ACTUATOR

Model DP-1

MANUAL CONTROL STATIONS

Model MC-1

AUTOMATIC SHUT-OFF VALVE 

Model ASV-1

FAIL-SAFE VALVE

Model FSV-1

FIXED TEMPERATURE RELEASE

Model FTR-1

SINGLE INTERLOCK SYSTEM

Model DV-5
Model DV-1
Model DV-3

DOUBLE INTERLOCK SYSTEM

Model DV-5
Model DV-1
Model DV-3

BUTTERFLY VALVES, WAFER AND LUG STYLE

Series 8000FP

CHECK VALVES

Model CV-2

FUSIBLE LINKS

Issue C, 50lb

PIPE LINE STRAINERS

Model A
Model B-1
Model C

FIRE DEPARTMENT CONNECTION

86 Straight 90 Degree

AUTOMATIC DRAIN BALL DRIP VALVE

Model F789

SECTIONAL TEST & DRAIN

Model F350

SIGHT FLOW CONNECTIONS

Model F1321

AUTOMATIC SUPERVISORY AIR SUPPLY

Model G16AC812

AUTOMATIC DRAIN VALVE

Model AD-1

SOLENOID VALVES




Electronic Dry Pipe Valve Accelerator

Deluge Valve

Tyco Fire & Building Products produces ductile iron, ASTM A-536, Grade 65-45-12 for all of its Grinnell grooved products. Once the base iron is produced, magnesium is added in precise measurements to develop the ductile iron grade. The metal is tested chemically, physically, and microscopically prior to being released for production. Once cast, the ductile iron is again checked to ensure conformance with these specifications.
 
Rubber Injection: Tyco Fire & Building Products understands the complexity of providing gaskets capable of exceeding customer demands. With state of the art rubber injection presses and tooling, we are able to mold several types of rubber compounds to meet the various needs of the mechanical market. The gaskets are manufactured in our facility in Alabama and each gasket is inspected to ensure it is defect free. Physical tests are performed on the gaskets to verify compliance with specifications such as ASTM D-2000.
 
The Paint Process: Grinnell Grooved Products are painted using a computer controlled semi-automatic process. This process ensures that each product is spray washed, dried, pre-heated, dipped and fully cured prior to being assembled or packaged for shipment. All painted parts are quality controlled to maintain consistent paint coverage and surface condition.
 
Tooling: Our engineering department provides product designs to our pattern centers as well as contracted pattern makers. The Grinnell patterns and our foundry molding machines are capable of providing the closest tolerance parts available using the green sand method of casting.

BUTTERFLY VALVE

Model BFV-1

CHECK VALVE

Model CV-1F

GROOVED FITTINGS

FLEXIBLE COUPLING

Figure 705

FLEXIBLE REDUCING COUPLING

Figure 716

FLEXIBLE COUPLING

Figure 707

RIGID COUPLING

Figure 772

MECHANICAL TEES

Figure 730

FLANGE ADAPTER

Figure 71




Flexible Reducing Coupling

Grooved Fittings

CPVC FIRE SPRINKLER PIPE FITTINGS

BlazeMaster CPVC Fire Sprinkler Pipe Fittings has becomes first non-metallic pipe approved for use in unfinished basements and exposed system risers.

EXPOSED SYSTEM RISERS

BlazeMaster CPVC Fire Sprinkler Pipe Fittings are now listed by Underwriters Laboratories, Inc. (UL) for use in unfinished basements with exposed solid wood joist installations in accordance with NFPA 13D and in exposed system risers in accordance with NFPA 13D and 13R. BlazeMaster CPVC pipe is the only non-metallic pipe listed by UL for these applications.

NO BLOCK HANGER

HEAD SET MOUNTING BRACKET




CPVC Fire Sprinkler Pipe and Fittings

No Block Hanger, Head Set Mounting Bracket

FIRE SPRINKLER DRAWING PACKAGES, SPRINKCAD N1, SPRINKCAD PRO II

SprinkCAD N1 and SprinkCAD Pro II are complete fire sprinkler drawing packages. A library of tools is included to allow the drawing of basic building units such as walls, ceilings, beams, etc., as well as sprinkler piping elements. Perform multiple calculations until the desired pipe sizes are achieved and stocklist the plan without the need to run another program. Integrated AutoCAD, head layout, piping, hydraulic calculation and stocklisting modules deliver a complete fire sprinkler solution.

No need to purchase AutoCAD as a separate package – N1 is built on AutoCAD 2002 technology. Existing drawings, catalogs, report and strategy files work unchanged with SprinkCAD N1 or SprinkCAD Pro II, which is compatible with AutoCAD 2000, 2000i and 2002. None of the procedures for designing, calcing, or listing a job need be changed. Existing drawings, catalogs, report and strategy files work unchanged with SprinkCAD Pro II.

FIRE SPRINKLER 3D DESIGN PACKAGE, SPRINKCAD 3D

SprinkCAD 3D is a comprehensive fire sprinkler 3D design package that produces true three-dimensional piping plans and views. SprinkCAD 3D includes the latest SprinkCALC and SprinkSLIC programs giving the designer total control of the necessary tools to create a complete project. SprinkCAD 3D can also be used with the optional SprinkFDT program to calculate the trip and water delivery times for dry type systems.

SprinkCAD 3D is a true 3D system – everything is designed in 3D-model space. The sprinkler designer can still work in a 2D plan view and use preset ISO views for viewing, thus making it an easy transition from 2D to 3D for those new to 3D views. Until now, creating three-dimensional objects in AutoCAD† has been slow and tedious. SprinkCAD 3D`s tools automate the 3D drawing process and allow sprinkler designers to lay out three-dimensional systems with relative ease.

ADVANCED HYDRAULIC CALCULATIONS, SPRINKCALC

Did the AHJ just ask for the advanced hydraulic calculations to be balanced and presented in metric using the Darcy-Weisbach method? No problem. Welcome to the newest and most advanced hydraulic calculation program available today...SprinkCALC. Metrics, U.S. units, mixed units... Hazen-Williams, Darcy-Weisbach... it doesn`t matter, SprinkCALC does it all and with ease. Work in familiar units and let the system do the conversions.

MULTILEVEL LOOPED DRY SYSTEM, SIMPLE TREE SYSTEM

Simply change the desired calculation method and in seconds view the new results. Quickly customize or build any pipe or fitting equivalent table for use on any material available today or tomorrow. Simple input screens allow complex sprinkler systems to be input and edited with ease. Calculate anything from a simple tree system to a multilevel looped dry system fed by a wet grid supplied by fire pump and city water.

SPRINKCODE, INTERACTIVE CODE SELECTOR

Quick! What`s the required density and area for...? Whether it`s an estimate or the final design, this interactive code selector is an essential member of your staff. The codes are not getting any simpler. When the complex details of storage height, ceiling height, aisle widths, pallets, bins, encapsulation, commodities, plastics, etc., make the difference between a bid and a contract, between a proper design or a review nightmare, you`ll be glad SprinkCODE is there to guide you.

FIRE PUMP CURVES, DISPLAY FLOW TEST CURVES

Intelligent interactive screens offer the choices needed to quickly and accurately narrow the options for the desired system density and coverage area, (or special application sprinkler). Within seconds the available options can be displayed for any NFPA 13 1999 code requirement. NFPA 13 1996, NFPA 231/231C 1995 and 1998 are also referenced. During the process of selecting the desired hazard options, simply select the NFPA 13 1999 requirement detail and the page of the code will appear for review or printing. The flow graph option quickly displays the 1.85 hydraulic graph and includes options to display flow test curves, fire pump curves and combined curves as desired.

SPRINKSLIC, FIRE SPRINKLER STOCK LISTING

Right on site! Ain`t that SLIC? The name of the game is ``pipe on the job`` and fire sprinkler stock listing is the bridge between design and installation. SprinkSLIC has power and depth yet is the easiest stand-alone stocklisting software to learn and use. Fast input and clear screens make creating and interpreting detailed pipe fabrication a breeze.

SprinkSLIC is built on the popular SLIC program that has been used industry wide for many years. This new version makes use of the latest technologies and brings this powerful program new life. Fully Windows compatible — say goodbye to DOS screens and printing problems

HYDRAULICALLY CALCULATED GRIDDED SYSTEMS, SPRINKFDT

Welcome to SprinkFDT, the first dramatic advancement in fire protection technology since the introduction of hydraulically calculated girded systems over 30 years ago. SprinkFDT is the latest software offering from SprinkCAD.

FLUID DELIVERY TIME

SprinkFDT (Fluid Delivery Time) now empowers a sprinkler designer to accurately predict the time it takes to trip a dry valve and deliver water to the remote area without the requirement of a physical trip test. Simple input and summary screens allow the user to quickly define a sprinkler system and evaluate the need for an accelerator or design modification.

DOUBLE INTERLOCK PREACTION SYSTEMS

James Golinveaux address the applicability of SprinkFDT to Double Interlock Preaction Systems in the 2002 edition of NFPA 13. SprinkFDT uses the same interface and file structure as our powerful SprinkCALC program making hydraulic calculation and delivery time calculation input even quicker. Simply calculate the system using SprinkCALC and then open SprinkFDT, select the open sprinklers and evaluate the dry system performance.




SprinkCAD N1, Fire Sprinkler Drawing Packages

SprinkCAD 3D, Fire Sprinkler 3D Design Package

FLOW SWITCH TESTER, ZONECHECK

Zonecheck complies with NFA 25 Quarterly Switch Test Requirements. It reduces testing time and saves up to 400 gallons per switch annually with simple key-switch operation. It doesn`t open inspectors test valve or activate the fire pump.

DSB-1 DRY SPRINKLER BOOT

The DSB-1 dry sprinkler boot will combat the potentially damaging temperature changes that can adversely affect dry sprinklers installed in freezers. DSB-1 dry sprinkler boot is an EPDM, 50 durometertype rubber boot designed for installation with all vertical, or pendent, dry sprinklers. Once installed, the boot creates an airtight seal, eliminating the build up of potentially dangerous condensation by maintaining consistent temperatures both outside and within the freezer area.

PRE-ACTION AUTOMATIC SPRINKLER, DD-1 CONDENSATE DRAIN, DELUGE SPRINKLER

The DD-1 Condensate Drain is a pre-manufactured drum drip for installation in dry-pipe sprinkler, deluge sprinkler and pre-action automatic sprinkler systems. The DD-1 Condensate Drain is made from electric-resistance-welded carbon and alloy steel mechanical tubing, ASTM A513. After the machining process is complete, the 1`` male outlets shall have a wall thickness greater than or equal to 0.133 inches and an O.D. of 1.315 inches. The DD-1 Condensate Drain is quick and easy to install.

AQUAMIST SYSTEM

The ``MCC`` Pump Skid Package is the self-contained control center of the AquaMist System. The compact skid unit has been professionally designed and assembled to ease system installation and to meet the most stringent project requirements. Power must be provided for the control cabinet and pump controller. Detection circuits must be installed and wired to the control cabinet.An adequate water supply must be piped to the pump supply piping inlet.

HEAVY DENSITY SPRINKLER SYSTEMS

AquaMist Systems utilize the newest and most unique nozzles developed and approved for fire protection. They offer an alternative to gaseous, foam, and heavy density sprinkler systems. By utilizing a higher pressure than a normal sprinkler system, but a 50-80% lower water flow, the AquaMist Systems use less water more effectively, reduce pipe sizes and labor costs, and minimize cleanup and water damage.




Flow Switch Tester, Zonecheck

AquaMist System
Visit our website for further information about our company       
 

Industry IDS, Inc.
Business Continuity Institute Continuity Central Open GIS Consortium, Inc Spatial Technologies Industry Association Ambulance Manufacturers Division
ACP
DELEGATES
12266
Conference Sectors  Case Studies  List of Papers  Exhibition Sectors  Vendor Presentation  List of Exhibitors  Industry News  Sponsors  All Exhibitors  All Papers  Sitemap  Registration Links ]

 :: IDS Plastics :: IDS Water ::IDS Packaging::IDS Publishing/Media ::IDS Healthcare Management ::IDS Environment::IDS Power/Energy::  

Industry IDS, Inc. – Online Tradeshow, Exhibition, & Buyers Guide Solutions